Removal Procedure
- Remove the center trim bezel from the instrument panel. Refer to
Instrument Panel Accessory Bezel Replacement
.
- Disconnect the electrical connectors from the HVAC control module.
- Remove the HVAC control module screws from the center trim bezel.
- Remove the HVAC control module from the center trim bezel.
Installation Procedure
- Install the HVAC control module to the center trim bezel.
Notice: Refer to Fastener Notice in the Preface section.
- Install the HVAC control module screws to the center trim bezel.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Connect the electrical connectors to the HVAC control module.
- Install the center trim bezel to the instrument panel. Refer to
Instrument Panel Accessory Bezel Replacement
.
Important: Any time a mode actuator or the HVAC control module is replaced, the HVAC control module must be calibrated to ensure proper air distribution.
- Calibrate the mode actuators by simultaneously pushing the A/C and RECIRC buttons on the HVAC control module 3 times each, within 2 seconds of initial push.
- Calibrate the mode actuators by simultaneously pushing the A/C and RECIRC buttons on the HVAC control module 3 times each, within 2 seconds of initial push.
• | The A/C and RECIRC button LED's will flash while this calibration is taking place. |
• | The calibration will take anywhere between 10-30 seconds depending on battery voltage. |
• | The LED's will quit flashing when the calibration is complete. |
- Cycle the ignition and verify proper operation.