Removal Procedure
- Remove the air cleaner intake duct. Refer to
Air Cleaner Inlet Duct Replacement
.
- Disconnect the mass air flow (MAF) sensor
electrical connector.
- Release the clamps (2) on the side of
the air cleaner assembly.
- Remove the air cleaner assembly lid (1) by tilting to release the
lid from the lower housing.
- Remove the air cleaner element (2) from
the lower housing (1).
Installation Procedure
- Install the air cleaner element (2) into
the lower housing (1).
- Install the air cleaner assembly lid (1)
by first engaging the hinge then lower the cover into the closed position.
- Fasten the clamps (2) on the side of the air cleaner assembly.
- Connect the MAF sensor electrical connector.
- Install the air cleaner intake duct. Refer to
Air Cleaner Inlet Duct Replacement
.