- Route the liquid line below the battery box and the ground lug.
Notice: Refer to Fastener Notice in the Preface section.
- Connect the negative battery cable nut to the wheelhouse.
Tighten
Tighten the nut to 12 N·m (106 lb in).
- Remove the protective caps from the condenser, the evaporator outlet hose, and the TXV.
- Install the new sealing washer to the liquid line. Refer to
Sealing Washer Replacement
.
- Route the condenser end of the liquid line into position.
- Install the liquid line to the condenser.
Important: Use a large pair of pliers to hold the fitting while tightening the nut. Be careful not to twist the line.
- Install the liquid line nut to the condenser.
Tighten
Tighten the nut to 20 N·m (15 lb ft).
- Install the bolt to retain the liquid line to the body.
Tighten
Tighten the nut to 9 N·m (80 lb in).
- Remove the protective cap from the TXV, the liquid line, and the evaporator outlet hose.
- Install new seal washers to the liquid line and the evaporator outlet hose. Refer to
Sealing Washer Replacement
.
- Install the liquid line and the evaporator outlet hose to the TXV.
- Install the liquid line and evaporator outlet hose retainer plate nut to the TXV.
Tighten
Tighten the nut to 20 N·m (15 lb ft).
- Install the four battery box bolts to the inside of the battery box.
Tighten
Tighten the nut to 15 N·m (11 lb ft).
- Install the battery box bolt to the outside of the battery box.
Tighten
Tighten the nut to 10 N·m (86 lb in).
- Install the battery. Refer to
Battery Replacement
.
- Install the liquid line to the strut tower.
- Install the liquid line nut to the strut tower.
Tighten
Tighten the nut to 9 N·m (80 lb in).
- Connect the harness and vent hose retainers to the liquid line.
- Install the surge tank. Refer to
Radiator Surge Tank Replacement
.
- Install the washer bottle. Refer to
Windshield Washer Solvent Container Replacement
.
- Install the left headlamp. Refer to
Headlamp Replacement
.
- Recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Test the affected A/C joints for leaks using
J 39400-A
.