Removal Procedure
- Remove the instrument panel compartment. Refer to
Instrument Panel Compartment Replacement
.
- Disconnect the electrical connector from the air temperature actuator.
- Remove the air temperature actuator screws from the HVAC module.
- Remove the air temperature actuator from the HVAC module.
Installation Procedure
- Align the air temperature actuator with the door shaft and rotate into position.
Notice: Refer to Fastener Notice in the Preface section.
- Install the air temperature actuator screws to the HVAC module.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Connect the electrical connector to the air temperature actuator.
Important: Any time an actuator or the HVAC control module is replaced, the HVAC control module must be calibrated to ensure proper air distribution.
- Calibrate the actuators. Refer to
Actuator Recalibration
.
- Cycle the ignition and verify proper operation.
- Install the instrument panel compartment. Refer to
Instrument Panel Compartment Replacement
.