• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | High Resistance | Open | Short to Voltage | Signal Performance |
---|---|---|---|---|---|
FTP Sensor Low Reference | -- | P0446, P0451 | P0446 | -- | P0451 |
FTP Sensor Signal | P0452 | -- | P0452 | P0453 | P0451, P0454 |
FTP Sensor 5-Volt Reference | P0452, P0530, P0641 | P0451 | P0446, P0453 | P0453, P0530, P0641 | -- |
Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
---|---|---|---|---|
Operating Conditions: With EVAP system vented to atmosphere | ||||
FTP Sensor Low Reference | 0 V | -- | 0 V | -- |
FTP Sensor Signal | 0 V | 0 V | 0-1.5 V | 5 V |
FTP Sensor 5-Volt Reference | 0 V | 0-1.5 V | 5 V |
The fuel tank pressure (FTP) sensor measures air pressure or vacuum in the evaporative emission (EVAP) system. The engine control module (ECM) supplies a 5-volt reference circuit and a low reference circuit to the FTP sensor. The FTP sensor signal voltage varies depending on EVAP system pressure or vacuum. The ECM also uses this FTP signal to determine atmospheric pressure for use in the engine-off small leak test, DTC P0442. Before using this signal as an atmospheric reference, it must first be re-zeroed.
• | DTC P0451 runs only when the engine-off natural vacuum small leak test, DTC P0442, executes. |
• | The number of times this test runs can range from 0-2 per engine-off period. The length of the test can be up to 10 minutes. |
DTCs P0452 and P0453 run continuously when the ignition is ON.
• | DTC P0454 runs only when the engine-off natural vacuum small leak test, DTC P0442, executes. |
• | This test can run once per engine-off period. The length of the test can be up to 10 minutes. |
• | A refueling event is not detected. |
This DTC will set if the controller is unable to re-zero the FTP sensor voltage within a calibrated range during the engine-off small leak test, DTC P0442.
The FTP sensor voltage is less than 0.1 volt for more than 5 seconds.
The FTP sensor voltage is more than 4.9 volts for more than 5 seconds.
If, during the engine-off natural vacuum small leak test, DTC P0442, the ECM detects an abrupt FTP signal change, other than a refueling event, this DTC will set. An abrupt change is defined as a change of 1 inch H2O in the span of 1 second.
• | DTCs P0451 and P0454 are Type A DTCs. |
• | DTCs P0452 and P0453 are Type B DTCs. |
• | DTCs P0451 and P0454 are Type A DTCs. |
• | DTCs P0452 and P0453 are Type B DTCs. |
• | A restriction in the EVAP canister or vent lines could prevent fuel vapor pressure from bleeding off fast enough. If the vent system cannot bleed off pressure fast enough, the re-zero procedure may not complete successfully, which could cause this code to set. By using the Purge Solenoid command on a scan tool, vacuum can be applied to the system instead of pressure. With the EVAP canister vent solenoid valve open and the EVAP canister purge solenoid valve commanded to 100 percent, the vacuum should not increase to more than 9 inches H2O. |
• | Ensure that the reference port on the FTP sensor is unobstructed. |
• | This diagnostic is designed to detect an unexpected abrupt voltage signal change from the FTP. |
• | Scan tool output controls, snapshot, and plot functions can help detect erratic sensor response. To look at the sensor signal under vacuum conditions, use Snapshot and the Purge/Seal function to capture data while commanding purge to 30 percent, then plot the data to look for erratic sensor operation. A similar inspection can be done for the pressure side of the sensor range by applying pressure with the J 41413-200 while taking a snapshot. |
• | Ensure that the reference port on the FTP sensor is unobstructed. |
Control Module References for scan tool information
J 41413-200 Evaporative Emission System Tester (EEST)
Important: Refer to the J 41413-200 operation manual for detailed instructions.
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the control module. |
⇒ | If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the control module. |
⇒ | If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the control module. |
⇒ | If greater than the specified range, test the signal circuit terminal 1 for a short to voltage. If the circuit tests normal, replace the control module. |
⇒ | If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the control module. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |