GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using the diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptor

DTC B1370 06: Device Ignition 1 Circuit Short to Ground or Open

Diagnostic Fault Information

Circuit

Short to Ground

High Resistance

Open

Short to Voltage

Signal Performance

Ignition 1 Voltage

B1370 06

--

B1370 06

--

B1370 06

Run/Crank Relay Coil Control

1

--

1

1

1

1. A fault in this circuit will cause multiple symptoms including no start and may cause B1370 in the SDM.

Circuit/System Description

The inflatable restraint sensing and diagnostic module (SDM) monitors the ignition 1 signal from the ignition switch. When the vehicle ignition switch is placed in the RUN or CRANK position, the switch supplies voltage to the SDM ignition 1 input terminal. If an open or short to ground in this SDM ignition 1 circuit is detected, then DTC B1370 will set.

Conditions for Running the DTC

Ignition voltage is between 9-16 volts.

Conditions for Setting the DTC

The SDM detects a short to ground or an open in the ignition 1 voltage circuit for at least 10 seconds when the ignition switch is in RUN or CRANK.

Action Taken When the DTC Sets

    • The SDM requests the instrument panel cluster (IPC) to illuminate the AIR BAG indicator.
    • The SDM determines its power mode only from the GMLAN power mode messages and discards the ignition 1 input for the remainder of the ignition cycle.

Conditions for Clearing the DTC

    • The condition for setting the DTC no longer exists.
    • A history DTC will clear once 100 malfunction-free ignition cycles have occurred.

Reference Information

Schematic Reference

SIR Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

SIR System Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs
    •  Connector Repairs

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Testing

Important: When removing connectors inspect for damage or corrosion. Damage or corrosion in the following requires repair or replacement of the affected.

   • SDM
   • SDM wiring harness

  1. Ignition OFF, remove the IGN 1 AIR BAG fuse.
  2. Ignition ON, test for 9-16V between the voltage supply side of the fuse and ground.
  3. If not within the specified range, refer to DTC B1370.
  4. Ignition OFF, disconnect the harness connector at the SDM and disconnect the X2 harness connector at the IP fuse block.
  5. Ignition OFF, test for less than 1 ohm between the ignition 1 circuit terminal 32 at the SDM harness connector and the IP fuse block terminal 10 X2.
  6. If greater than the specified range, test the circuit for an open/high resistance.
  7. Ignition ON, test for less than 1 volt between the ignition 1 circuit terminal 32 at the SDM harness connector and the IP fuse block terminal 10 X2.
  8. If greater than the specified value, test the circuit for a short to voltage.
  9. If all circuits test normal, replace the SDM.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Control Module References for SDM replacement, setup, and programming
    •  SIR/SRS Wiring Repairs