Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Important:
• Use new O-rings lubricated with 525 viscosity mineral oil. • Hold the A/C refrigerant pressure switch mount with an open end wrench to avoid bending the liquid line.
Tighten
Tighten the A/C refrigerant pressure switch (2) to 10 N·m (7.0 lb ft).