During the course of a vehicle's useful life, certain situations may arise which will necessitate the disposal of a live (undeployed) pretensioner. The following information covers the proper procedures for the disposing of a live pretensioner. Deploy the pretensioner before disposal. Do not dispose of a live pretensioner through normal disposal channels.
CAUTION: In order to prevent accidental deployment of the pretensioner which could cause personal injury, do not dispose of an undeployed pretensioner as normal shop waste. The undeployed pretensioner contains substances that could cause severe illness or personal injury if the sealed container is damaged during disposal. Use the following deployment procedures to safely dispose of an undeployed pretensioner. Failure to dispose of a pretensioner as instructed may be a violation of federal, state, or local laws.
The pretensioner can be deployed inside or outside of the vehicle. The method used depends upon the final disposition of the vehicle. Review the following procedures in order to determine which will work best in a given situation:
Refer to Inflator Module Handling and Scrapping Deployment Inside Vehicle (Vehicle Scrapping Procedure) for deploying the pretensioners inside the vehicle.
Deploy the seat belt pretensioners outside of the vehicle when the vehicle will be returned to service. Situations that require deployment outside of the vehicle include the following:
• | Using the SIR diagnostics, you determine that the seat belt pretensioner does not function properly. |
• | The seat belt pretensioner is scratched or damaged. |
• | The seat belt pretensioner pigtail, if equipped, is damaged. |
• | The seat belt pretensioner connector is damaged. |
• | A seat belt pretensioner connector terminal is damaged. |
Deployment and disposal of a malfunctioning seat belt pretensioner is subject to any required retention period.
CAUTION: In order to prevent accidental deployment of the pretensioner which could cause personal injury, do not dispose of an undeployed pretensioner as normal shop waste. The undeployed pretensioner contains substances that could cause severe illness or personal injury if the sealed container is damaged during disposal. Use the following deployment procedures to safely dispose of an undeployed pretensioner. Failure to dispose of a pretensioner as instructed may be a violation of federal, state, or local laws.
• | J 38826 SIR Deployment Harness |
• | An appropriate pigtail adapter |
CAUTION: When you are deploying a pretensioner for disposal, perform the deployment procedures in the order listed. Failure to follow the procedures in the order listed may result in personal injury.
Important: The rapid gas expansion involved with deploying a pretensioner is very loud. Notify all the people in the immediate area that you intend to deploy the seat belt pretensioner.
Some gas will be visible after deployment. Exposure to this gas is not a health concern. The pretensioner can be handled immediately after deployment.