This DTC identifies a malfunction within the SDM.
Ignition 1 voltage is within the normal operating voltage range.
An internal SDM malfunction exists.
The SDM commands the AIR BAG indicator ON.
The condition responsible for setting the DTC no longer exists and the scan tool Clear DTCs function is used.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Schematic Reference: SIR Schematics Connector End View Reference: SIR Connector End Views | ||||
1 | Did you perform a Diagnostic System Check - SIR? | -- | Go to Step 2 | |
2 | Are other DTCs current in addition to B1100? | -- | Go to applicable DTC | Go to Step 3 |
3 |
Is the voltage as specified? | 10-14V | Go to Step 5 | Go to Step 4 |
4 | Test SDM ignition positive voltage circuit for an open or short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 7 | Go to Step 6 |
5 | Test SDM ground circuits for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 7 | Go to Step 6 |
6 | Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Did you complete the replacement? | -- | Go to Step 7 | |
7 |
Does the DTC reset? | -- | Go to Step 2 | System OK |