Testing for Electrical Intermittents for Pontiac Vibe - FWD 2003
Perform the following procedures while wiggling the harness from side to side.
Continue this at convenient points (about 6 inches apart) while watching the
test equipment.
If the fault is not identified, perform the procedure below using the MIN MAX
feature on the J 39200
DMM.
This feature allows you to manipulate the circuit without having to watch the J 39200
. The J 39200
will generate an audible tone when a
change is detected.
Important: The J 39200
must be
used in order to perform the following procedure since the J 39200
can monitor current, resistance or voltage while recording
the minimum (MIN), and maximum (MAX) values measured.
- Connect the J 39200
to both sides of a suspected connector (still connected), or from one end
of a suspected circuit to the other. Refer to
Troubleshooting with a Digital Multimeter
for information on connecting the J 39200
to the circuit.
- Set the rotary dial of the J 39200
to the V (AC) or V (DC) position.
- Press the range button of the J 39200
in order to select the desired voltage range.
- Press the MIN MAX button of the J 39200
. The J 39200
displays 100 ms RECORD and emits an audible tone (beep).
Important: The 100 ms RECORD mode is the length of time an input must stay at a
new value in order to record the full change.
- Simulate the condition that is potentially causing the intermittent connection,
either by wiggling the connections or the wiring, test driving, or performing other
operations. Refer to
Inducing Intermittent Fault Conditions
.
- Listen for the audible Min Max Alert which indicates that a new minimum
or maximum value has been recorded.
- Press the MIN MAX button once in order to display the MAX value and note
the value.
- Press the MIN MAX button again in order to display the MIN value and note
the value.
- Determine the difference between the MIN and MAX values.
| • | If the variation between the recorded MIN and MAX voltage values is 1 volt
or greater an intermittent open or high resistance condition exists. Repair the condition
as necessary. |
| • | If the variation between the recorded MIN and MAX voltage values is less
than 1 volt an intermittent open or high resistance condition does not exist. |