The inflatable restraint IP module deployment loop consists of a dual stage inflatable restraint IP module, the IP module high and IP module low circuits. There are 2 shorting bar used in the inflatable restraint IP module connector which will short together the IP module - high and IP module low circuits when the connector is disconnected, this will help to prevent unwanted deployment of the inflator module during servicing. When the ignition is turned ON, the inflatable restraint sensing and diagnostic module (SDM) performs continuous diagnostic tests on the deployment loops to check for proper circuit continuity and for shorts to ground or voltage. If a malfunction is detected, a DTC will be stored.
Ignition 1 Voltage is within the normal operating voltage range.
• | DTC B0105 will set when the SDM detects a low resistance condition in the IP module deployment loop. |
• | DTC B0106 will set when the SDM detects a high resistance condition in the IP module deployment loop. |
• | DTC B0107 will set when the SDM detects a short to ground in the IP module deployment loop. |
• | DTC B0108 will set when the SDM detects a short to voltage in the IP module deployment loop. |
The SDM commands the AIR BAG indicator ON.
The condition responsible for setting the DTC no longer exists and the scan tool Clear DTCs function is used.
Thoroughly inspect the wiring and the connectors. An incomplete inspection of the wiring and the connectors may result in a misdiagnosis, causing a part replacement with the reappearance of the malfunction.
The following are possible causes of the malfunction:
• | A short between the IP module - high and the IP module - low circuits. |
• | An open or high resistance in the IP module - high or the IP module - low circuits. |
• | A short to ground in the IP module - high or the IP module - low circuits. |
• | A short to voltage in the IP module - high or the IP module - low circuits. |
• | A malfunctioning inflatable restraint IP module. |
• | An internal SDM malfunction. |
If an intermittent malfunction exists, refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table.
Tests to see if the malfunction is caused by the inflatable restraint IP module.
Tests to see if the malfunction is caused by the inflatable restraint IP module.
If DTC B0105 is present, test for a short between the IP Module High and IP Module Low circuits.
If DTC B0106 is present, test the IP Module High and IP Module Low circuits for an open or high resistance.
If DTC B0107 is present, test the IP Module High and IP Module Low circuits for a short to ground.
If DTC B0108 is present, test the IP Module High and IP Module Low circuits for a short to voltage.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: SIR Schematics Connector End View Reference: SIR Connector End Views | |||
1 | Did you perform A Diagnostic System Check - SIR? | Go to Step 2 | |
2 | Is DTC B0105, B0106, B0107 or B0108 set as a current DTC? | Go to Step 3 | Go to Diagnostic Aids |
3 |
Does the connector exhibit any signs of damage or corrosion? | Go to Step 4 | Go to Step 5 |
4 |
Did you complete the replacement? | Go to Step 13 | -- |
5 | Is DTC B0106, B0107 or B0108 set as a current DTC? | Go to Step 7 | Go to Step 6 |
6 | Is DTC B0105 set as a current DTC? | Go to Step 8 | -- |
Does the scan tool indicate that DTC B0106, B0107, or B0108 is current? | Go to Step 9 | Go to Step 11 | |
Does the scan tool indicate that DTC B0105 is current? | Go to Step 9 | Go to Step 11 | |
9 |
Did you find and correct the condition? | Go to Step 13 | Go to Step 10 |
Did you find and correct the condition? | Go to Step 13 | Go to Step 12 | |
11 |
Did you complete the replacement? | Go to Step 13 | -- |
12 | Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Did you complete the replacement? | Go to Step 13 | -- |
13 |
Does the DTC reset? | Go to Step 2 | System OK |