Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: Starting and Charging Schematics Connector End View Reference: Engine Electrical Connector End Views | ||||
1 | Did you review the following description and operations and perform the necessary inspections? | -- | Go to Step 2 | |
2 | Start the engine. Does the charge indicator remain illuminated? | -- | Go to Step 3 | Go to Testing for Intermittent Conditions and Poor Connections |
3 |
Is the voltage within the specified value? | 12.5-15.5 V | Go to Step 4 | Go to Charging System Test |
4 |
Does the charge indicator remain illuminated? | -- | Go to Step 7 | Go to Step 5 |
5 |
Is the voltage measured near the specified value? | B+ | Go to Step 6 | Go to Step 8 |
6 | Inspect for poor connection at the generator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 9 |
7 | Repair the short to ground in the charge indicator circuit. Refer to Wiring Repairs . Did you complete the repair? | -- | Go to Step 10 | -- |
8 | Repair the high resistance or open in the sense circuit of the generator. Refer to Wiring Repairs . Did you complete the repair? | -- | Go to Step 10 | -- |
9 | Replace the generator. Refer to Generator Replacement . Did you complete the repair? | -- | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |