Removal Procedure
- Disconnect the electrical connector (1)
from the secondary air injection (AIR) pressure sensor (2).
- Remove the 2 fasteners of the AIR pressure sensor (2).
- Remove the AIR pressure sensor (2) from the shut-off valve (3).
Installation Procedure
- Install the AIR pressure sensor (2)
to the shut-off valve (3).
Notice: Refer to Fastener Notice in the Preface section.
- Secure the AIR pressure sensor with 2 fasteners.
Tighten
Tighten the 2 fasteners to 5 N·m
(44 lb in).
- Connect the electrical connector (1) to the AIR pressure sensor (2).