Removal Procedure
- Disconnect the electrical connector (1)
from the evaporative emission (EVAP) canister purge valve (2).
- Disconnect the 2 vacuum hoses (4) from the EVAP canister purge
valve (2).
- Remove the EVAP canister purge valve from the air inlet duct hose.
- Inspect the EVAP canister purge valve and the EVAP purge system for carbon
particle contamination before replacing the EVAP canister purge valve.
Installation Procedure
- Insert the locator pin (3) of the
purge valve into the mounting hole on the air inlet duct.
- Connect the 2 vacuum hoses (4) to the EVAP canister purge valve
(2).
- Connect the electrical connector (1) to the EVAP canister purge
valve (2).