Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views | |||
1 | Did you review the Air Delivery Description and Operation and the Air Temperature Description and Operation perform the necessary inspections? | Go to Step 2 | |
2 | Operate the blower motor at each speed. Does the blower motor operate at any speed? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 |
Does the test lamp light? | Go to Step 12 | Go to Step 4 |
4 | Test the blower motor supply voltage circuit for an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 5 |
5 | Test the blower motor ground circuit for an open between the blower motor and S223. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 6 |
6 | Test that the heater relay is open between terminals 3 and 5 and that there is continuity between terminals 3 and 4. Did the relay test OK? | Go to Step 7 | Go to Step 11 |
7 | Test the heater relay coil and switch supply voltage circuits for an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 8 |
8 | Test the heater relay control circuit for an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 9 |
9 | Test the blower switch ground circuit for an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 10 |
10 | Inspect for a poor connection at the harness connector of the blower switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 13 |
11 | Inspect for a poor connection at the harness connector of the heater relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 14 |
12 | Inspect for a poor connection at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 15 |
13 | Replace the blower switch. Refer to Blower Switch Replacement . Did you complete the replacement? | Go to Step 16 | -- |
14 | Replace the heater relay. Refer to Blower Motor Relay Replacement . Did you complete the replacement? | Go to Step 16 | -- |
15 | Replace the blower motor. Refer to Blower Motor Replacement . Did you complete the replacement? | Go to Step 16 | -- |
16 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |