An ignition voltage is supplied directly to the evaporative emission (EVAP) canister vent valve. The control module controls the EVAP vent valve by grounding the control circuit via an internal driver switch. The primary function of the driver is to supply ground for the controlled component. The control module monitors the status of the driver. If the control module detects an incorrect voltage for the commanded state of the driver, DTC P0449 sets.
This diagnostic procedure supports the following DTC:
DTC P0449 Evaporative Emissions (EVAP) Vent Solenoid Control Circuit
• | DTC P0606 is not set. |
• | The ignition 1 voltage is more than 11 volts. |
• | DTC P0449 runs continuously once the above conditions are met. |
The ECM detects that the commanded state of the driver and the actual state of the control circuit do not match, for more than 1 second.
• | The control module illuminates the malfunction indicator lamp (MIL) when the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The control module stores this information in the Freeze Frame/Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
The numbers below refer to the step numbers on the diagnostic table.
A click should be heard or felt when the valve operates. Ensure that both the ON and the OFF states are commanded. Repeat the commands as necessary.
This step verifies that the ECM is providing ground to the EVAP vent valve.
This step tests if the EVAP vent valve control circuit is grounded.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Engine Controls Schematics Connector End View Reference: Engine Control Module Connector End Views or Engine Controls Connector End Views | |||
1 | Did you perform the Diagnostic System Check - Engine Controls? | Go to Step 2 | |
Do you hear or feel a click from the EVAP vent valve when the valve is commanded ON and OFF? | Go to Step 3 | Go to Step 4 | |
3 |
Did the DTC fail this ignition? | Go to Step 4 | Go to Intermittent Conditions |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 11 |
Does the test lamp turn ON and OFF with each command? | Go to Step 9 | Go to Step 6 | |
Does the test lamp remain illuminated with each command? | Go to Step 8 | Go to Step 7 | |
7 | Test the control circuit of the EVAP vent solenoid for a short to voltage or for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 10 |
8 | Test the control circuit of the EVAP vent valve for a short to ground. Refer to Testing for Short to Ground and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 10 |
9 | Inspect for poor connections at the vent valve. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 12 |
10 | Inspect for poor connections at the ECM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 13 |
11 | Repair the ignition 1 voltage circuit of the EVAP vent valve for an open or for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 14 | -- |
12 | Replace the EVAP vent valve. Refer to Evaporative Emission Canister Vent Solenoid Valve Replacement . Did you complete the replacement? | Go to Step 14 | -- |
13 | Replace the ECM. Refer to Engine Control Module Replacement . Did you complete the replacement? | Go to Step 14 | -- |
14 |
Did the DTC fail this ignition? | Go to Step 15 | Go to Step 2 |
15 | Observe the Capture Info with a scan tool. Are there any DTCs that have not been diagnosed? | System OK |