Notice: Do not insert test equipment probes (DVOM etc.) into any connector or fuse block terminal. The diameter of the test probes will deform most terminals.
A deformed terminal will cause a poor connection, which will result in a system failure. Always use the J-35616 GM-Approved Terminal Test Kit in order to front probe terminals. Do not use paper clips or other substitutes to probe terminals.
When using the J-35616 GM-Approved Terminal Test Kit, ensure the terminal test adapter choice is the correct size for the connector terminal. Do not visually choose the terminal test adapter because some connector terminal cavities
may appear larger than the actual terminal in the cavity. Using a larger terminal test adapter will damage the terminal. Refer to the J-35616 GM-Approved Terminal Test Kit label on the inside of the J-35616 GM-Approved Terminal Test
Kit for the correct adapter along with the connector end view for terminal size.
The following
procedure measures the voltage at a selected point in a circuit.
- Disconnect the electrical harness connector for the circuit being
tested, if necessary.
- Enable the circuit and/or system being tested. Use the following
methods:
• | Turn ON the ignition, with the engine OFF. |
• | Turn ON the circuit and/or system with a scan tool in Output Controls. |
• | Turn ON the switch for the circuit and/or system being tested. |
- Select the V (AC) or V (DC) position on the DMM.
- Connect the positive lead of the DMM to the point of the circuit
to be tested.
- Connect the negative lead of the DMM to a good ground.
- The DMM displays the voltage measured at that point.