Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Inspect the chime module connector to make sure it is connected properly. Is the connector disconnected or partially disconnected? | -- | Go to Step 2 | Go to Step 3 |
2 | Connect the electrical connector for the chime module. Is the repair complete? | -- | System OK | -- |
3 | Inspect fuse F4. Is fuse F4 open? | -- | Go to Step 4 | Go to Step 5 |
4 |
Is the repair complete? | -- | System OK | -- |
5 |
Is the specified voltage available at fuse F4? | 11-14 V | Go to Step 7 | Go to Step 6 |
6 | Repair the power supply circuit for fuse F4. Is the repair complete? | -- | System OK | -- |
7 |
Does the voltage equal the specified value? | 11-14 V | Go to Step 9 | Go to Step 8 |
8 | Repair the open circuit between fuse F4 and the chime module connector. Is the repair complete? | -- | System OK | -- |
9 | With the chime module disconnected, use an ohmmeter to check the continuity between terminal 5 of the chime module connector and ground. Does the ohmmeter indicate the specified value? | 0 ohms | Go to Step 11 | Go to Step 10 |
10 | Repair the open circuit between terminal 5 of the chime module connector and ground. Is the repair complete? | -- | System OK | -- |
11 |
Does the ohmmeter indicate the specified value? | 0 ohms | Go to Step 12 | Go to Step 13 |
12 | Replace the chime module. Is the repair complete? | -- | System OK | -- |
13 |
Does the ohmmeter indicate the specified value? | 0 ohms | Go to Step 15 | Go to Step 14 |
14 | Repair the open circuit between the door contact switch and terminal 4 of the chime module. Is the repair complete? | -- | System OK | -- |
15 | Replace the door contact switch. Is the repair complete? | -- | System OK | -- |