This diagnostic procedure supports the following DTC:
DTC P0711Transmission Fluid Temperature (TFT) Sensor Circuit Performance
| • | Transmission fluid temperature is less than 15°C (59°F) | 
| • | Vehicle speed is 40 km/h (25 mph) or greater. | 
| • | Conditions above continues for 10 minutes or more. | 
| • | The TCM will request the illumination of malfunction indicator lamp (MIL) and store the DTC when the TCM detects a failure on the first ignition cycle. | 
| • | No timing solenoid control N-D | 
| • | The TCM turns OFF the MIL when no further failures are detected on the next 3 consecutive ignition cycles. | 
| • | The scan tool can clear the DTC from the TCM history. | 
| • | The TCM clears the DTC from the TCM history memory after 40 consecutive ignition cycles without fault. | 
| • | The TCM detects the temperature of the transmission fluid is between 0-150°C (32-302°F) for 10 seconds continuously. | 
| • | The wiring harness or the connector between the TFT sensor and the TCM | 
| • | The TFT sensor | 
| • | The TCM | 
Step  | Action  | Values  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Diagnostic System Check - Automatic Transmission?  | --  | Go to Step 2  | |
2  | 
 Is the malfunction indicator lamp (MIL) ON?  | --  | Go to Step 3  | Go to Step 5  | 
3  | 
 Is DTC P0711 displayed?  | --  | Go to Step 4  | Go to Step 5  | 
4  | 
 Is the measurement within the specified values?  | 10°C (50°F) 5.80-7.09 KΩ 110°C (230°F) 0.231-0.263 KΩ  | Go to Step 6  | Go to Step 7  | 
5  | Repair the temporary connection failure of the connector. Refer to Wiring Harness and Connector Inspection Diagnosis . Did you complete the repair?  | --  | System OK  | --  | 
6  | 
 Is the connection condition OK?  | --  | Go to Step 8  | Go to Step 5  | 
7  | 
 Is the measurement within the specified values?  | 10°C (50°F) 5.80-7.09 KΩ 110°C (230°F) 0.231-0.263 KΩ  | Go to Step 9  | Go to Step 10  | 
8  | 
 Is DTC displayed?  | --  | Go to Step 2  | System OK  | 
9  | 
 Is the condition OK?  | --  | System OK  | Go to Step 5  | 
10  | 
 Is the condition found?  | --  | Go to Step 12  | Go to Step 11  | 
11  | 
 Is the condition OK?  | --  | System OK  | Go to Step 5  | 
12  | Replace the TFT sensor. Refer to Transmission Fluid Temperature Sensor Inspection . Did you complete the replacement?  | --  | System OK  | --  |