• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
ignition Voltage Circuit | P0030, P0036, P0102, P0135, P0141, P0443, P0597, P0598 | P0443 | -- | -- |
EVAP Canister Purge Valve Control Circuit | P0443 | P0443 | P0443 | -- |
The evaporative emission (EVAP) canister purge valve is used to purge fuel vapor from the EVAP canister to the intake manifold. The EVAP canister purge valve is pulse width modulated (PWM). Ignition voltage is supplied directly to the EVAP canister purge valve. The engine control module (ECM) controls the solenoid by grounding the control circuit with a solid state device called a driver. The driver is equipped with a feedback circuit that is pulled-up to a voltage. The ECM can determine if the control circuit is open, shorted to ground, or shorted to a voltage by monitoring the feedback voltage.
• | The ignition is ON. |
• | The ignition voltage is between 11-18 volts. |
• | The DTCs runs continuously once the above conditions are met. |
The ECM detects that the commanded state of the driver and the actual state of the control circuit do not match for greater than 5 seconds.
DTC P0443 is a Type B DTC.
DTC P0443 is a Type B DTC.
Evaporative Emission Control System Description
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
• | EVAP Purge Sol Short Gnd Test Status |
• | EVAP Purge Sol Open Test Status |
• | EVAP Purge Sol Short Volts Test Status |
• | Each parameter should display OK or Not Run. |
⇒ | If the test lamp does not illuminate, test the ignition voltage circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition voltage circuit fuse is open, test all components connected to the ignition voltage circuit and replace as necessary. |
⇒ | If less than the specified range, test the control circuit for a short to ground or an open/high resistance. If the circuit/connections test normal, replace the ECM. |
⇒ | If greater than the specified range, test the control circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If the circuit voltage does not correspond to the specified values, replace the ECM. |
⇒ | If not within the specified range, replace the EVAP purge solenoid. |
⇒ | If not the specified value, replace the EVAP purge solenoid. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for engine control module replacement, setup, and programming |