Diagnostic Instructions
Circuit/System Description
The reading lamps are supplied voltage through the inadvertent power supply circuit from the BCM.
Reference Information
Schematic Reference
Interior Lights Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
Interior Lighting Systems Description and Operation
Electrical Information Reference
Scan Tool Reference
Control Module References for Scan Tool Information
Circuit/System Verification
Ignition ON, turn the reading lamps on and off. The reading lamps should turn on and off.
Circuit/System Testing
- Ignition OFF, disconnect the harness connector at an affected courtesy/reading lamp center.
- Test for less than 1 ohm of resistance between the ground circuit terminal B and ground.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
- Ignition ON, verify that a test lamp illuminates between the inadvertent power supply circuit terminal C and ground.
⇒ | If the test lamp does not illuminate, test the inadvertent power supply circuit for a short to ground or an open/high resistance. If the circuit tests normal replace the BCM. |
- Connect the harness connector at the courtesy/reading lamp center, and remove the reading lamp bulb.
- Connect a test lamp across the bulb terminals.
- Ignition ON, turn the reading lamp switch on and off. The test lamp should turn on and off when changing between the commanded states.
⇒ | If the test lamp is always on, replace the affected courtesy/reading lamp center. |
⇒ | If the test lamp is always off, replace the affected courtesy/reading lamp center. |
- If all circuits test normal, test or replace the affected reading lamp bulb.
Repair Instructions
Perform the
Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for BCM replacement, programming, and setup.