• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
TBC 2 Fuse B+ | 2 | 2 | -- | -- |
TBC 5 Fuse B+ | 2 | 2 | -- | -- |
I/P Dimming Voltage Reference | 1 | 1 | 1 | -- |
I/P Dimmer Switch Control | 1 | 1 | 1 | -- |
I/P Lamps Dimmer Switch Signal | 2 | 2 | 2 | -- |
Indicator Dimming Control | B2625 00 | 3 | 3 | -- |
LED Backlight Dimming Signal | B2610 00 | 3 | 3 | -- |
LED Backlight Dimming Control | 3 | 3 | 3 | -- |
Memory Switch Backlight Control | 4 | 4 | 4 | -- |
I/P Dimmer Low Reference | 1 | 1 | 1 | -- |
Memory Switch Backlight Low Reference | -- | 4 | -- | -- |
Headlamp Switch Ground | -- | 1 | -- | -- |
1. Dimmer Switch Malfunction 2. Interior Backlighting Malfunction -- Incandescent 3. Interior Backlighting Malfunction -- LED 4. Memory Switch Indicator Malfunction |
The body control module (BCM) directly sends a 5-volt reference voltage to the instrument panel (I/P) dimmer switch which is then adjusted based on the I/P dimmer switch position and returned as a low reference and a signal to the BCM. The BCM uses this signal to directly control the desired level of instrument panel illumination lamp intensity.
The battery voltage must be between 9-16 volts.
• | The dimmer switch 5-volt reference is greater than 6.15 volts. |
• | The dimmer switch 5-volt reference is less than 3.85 volts. |
• | The dimmer switch signal circuit is greater than 4.83 volts. |
The interior dimming backlights and indicators are inoperative or at full intensity whenever on.
• | This DTC will clear on current status after the condition for setting the fault is corrected. |
• | A history DTC will clear after 100 consecutive ignition cycles without a fault present. |
Interior Lights Dimming Schematics
Interior Lighting Systems Description and Operation
Control Module References for scan tool information
⇒ | If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If greater than the specified range, test the signal circuit terminal 8 for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If less than the specified range, test the signal circuit for short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, programming, and setup |