Blower Motor Control Processor Replacement for Saab 9-7x 2009
Removal Procedure
- Remove the right closeout panel. Refer to
Instrument Panel Insulator Panel Replacement - Right Side.
- Disconnect the electrical connector from the blower motor.
- Disconnect the electrical connector (3) from the blower motor control processor (1).
- Remove the blower motor control processor mounting screws (2).
- Remove the blower motor control processor (1).
Installation Procedure
- Install the blower motor control processor (1).
Caution: Refer to Fastener Caution in the Preface section.
- Install the blower motor control processor mounting screws (2) and tighten to
1.9 N·m (17 lb in).
- Connect the electrical connector (3) to the blower motor control processor (1).
- Connect the electrical connector to the blower motor.
- Install the right closeout panel. Refer to
Instrument Panel Insulator Panel Replacement - Right Side.