Install the 3 bolts that retain the window regulator assembly to the door and tighten to
10 N·m (88 lb in).
Connect the electrical connector to the regulator motor.
Remove the window support and lower the window onto the regulator window carrier.
Loosely tighten the regulator window carrier bolts.
Operate the window upward to the full up position, ensuring the window remains in the run channels. Tighten the regulator window carrier bolts to 10 N·m (88 lb in).