• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Front Fog Lamp Relay B+ | B2530 00 | B2530 00 | -- | -- |
Front Fog Lamp Control | 1 | 1 | 1 | -- |
Front Fog Lamp Switch Signal | B2527 00 | 2 | 2 | -- |
Front Fog Lamp Relay and Indicator Control | B2530 00 | B2530 00 | B2530 00 | -- |
Front Fog Lamp Ground | -- | 1 | -- | -- |
Headlamp Switch Ground | -- | 4 | -- | -- |
1. Fog Lamp Malfunction 2. Fog Lamp Switch Malfunction |
The front fog lamp relay coil is supplied with battery voltage when the ignition is in the RUN or CRANK position. The front fog lamp relay switch is supplied with battery voltage at all times. The front fog lamp switch signal circuit is grounded momentarily by pressing the front fog lamp switch. The body control module (BCM) energizes the front fog lamp relay by applying ground to the front fog lamp relay control circuit. When the front fog lamp relay is energized, the relay switch contacts close and battery voltage is applied through the FRONT FOG fuse to the front fog lamp control circuit which illuminates the front fog lamps.
The battery voltage must be between 9-16 volts.
The front fog lamp switch signal circuit is shorted to ground for 15 minutes.
The front fog lamps will be inoperative.
• | This DTC will clear on current status after the condition for setting the fault is corrected. |
• | A history DTC will clear after 100 consecutive ignition cycles without a fault present. |
Exterior Lighting Systems Description and Operation
Control Module References for scan tool information
⇒ | If not the specified value test the front fog lamp switch signal circuit terminal E for a short to ground. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, programming, and setup |