The HVAC control module monitors the evaporator temperature via the evaporator temperature sensor. When the air is cold, the sensor resistance and signal voltage are high. When the air is warm, the sensor resistance and signal voltage are low.
This diagnostic procedure supports the following DTC:
• | DTC P0537: Evaporator Air Temperature Sensor Circuit Low Voltage |
• | DTC P0537: Evaporator Air Temperature Sensor Circuit High Voltage |
The ignition is turned ON.
The HVAC control module detects the evaporator temperature sensor signal circuit is less than 0.443 volts or greater than 4.55 volts.
The air conditioning (A/C) compressor will be disabled.
• | The DTC will become history if the HVAC control module no longer detects a failure. |
• | The history DTC will clear after 50 fault-free ignition cycles. |
• | The DTC can be cleared with a scan tool. |
The numbers below refer to the step numbers on the diagnostic table.
This step tests for the proper operation of the circuit in the high voltage range.
This step tests for the proper operation of the circuit in the low voltage range. If the fuse in the jumper opens upon performing this test, the signal circuit has a short to voltage.
Step | Action | Values | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views | ||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |||||||
2 |
Refer to Air Conditioning Evaporator Core Replacement . Is the Evaporator Temp parameter greater than the specified value? | 1.0 ohms | Go to Step 8 | Go to Step 3 | ||||||
3 |
Does the DMM indicate that the Evaporator Temp signal voltage parameter is within the specified value range? | 0.443-4.55 V | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 4 | ||||||
Refer to Air Conditioning Evaporator Core Replacement . Is the Evaporator Temp signal voltage parameter greater than the specified value? | 4.55 V | Go to Step 5 | Go to Step 6 | |||||||
Is the Evaporator Temp voltage parameter less than the specified value? | 0.443 V | Go to Step 9 | Go to Step 7 | |||||||
6 | Test the signal circuit of the evaporator temperature sensor for a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 10 | ||||||
7 | Test the signal circuit of the evaporator temperature sensor for one of the following conditions:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 8 | ||||||
8 | Test the low reference circuit of the evaporator temperature sensor for one of the following conditions:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 9 | ||||||
9 | Inspect for poor connections at the harness connector of the evaporator temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 11 | ||||||
10 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 12 | ||||||
11 | Replace the evaporator temperature sensor. Refer to Air Conditioning Evaporator Core Replacement . Did you complete the replacement? | -- | Go to Step 13 | -- | ||||||
12 | Replace the HVAC control module. Refer to Control Module References for HVAC control module replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 13 | -- | ||||||
13 |
Does the DTC reset? | -- | Go to Step 2 | System OK |