Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor operates with the HVAC controls in the OFF position. | ||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |
2 |
Important: Be sure that the blower motor housing is not shorted to a grounded surface this will cause the blower motor to always be on in high speed.
Is the blower motor OFF? | -- | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | With the scan tool observe the Blower Motor PWM Speed parameter in the Heating and Air Conditioning data list. Does the scan tool indicate that the Blower Motor PWM Speed parameter is near the specified value? | 0% | Go to Step 4 | Go to Step 7 |
4 |
Is the blower motor OFF? | -- | Go to Step 7 | Go to Step 5 |
5 | Test the blower motor speed control circuit of the HVAC control module for an short to ground, or short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 6 |
6 | Inspect for poor connections at the harness connector of the blower motor control processor. Refer to Wiring Repairs and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 8 |
7 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 9 |
8 | Replace the blower motor control processor. Refer to Blower Motor Control Processor Replacement . Did you complete the replacement? | -- | Go to Step 10 | -- |
9 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |