A/C Disengage Reason: The scan tool displays one of the following
reasons why the powertrain control module (PCM) or engine control module (ECM) has
disengaged the A/C compressor; None, System Voltage, WOT, CKP, Learn Active, Engine
Run Time, Coolant Hot, Anti Stall, A/C Pressure, Engine Speed, Trans Engine Speed,
A/C Pressure Sensor, Low Voltage, High Voltage, Outside Air, Temp, A/C Switched Off.
A/C High Side Pressure Sensor: The scan tool displays 0-3450 kPa
(0-500 psi). The voltage applied to the PCM/ECM input from the A/C refrigerant
pressure sensor is converted to a pressure value.
A/C High Side Pressure Sensor: The scan tool displays 0-5 volts.
The voltage applied to the PCM/ECM input for the A/C refrigerant pressure sensor.
A/C LED: The scan tool displays the On/Off status of the A/C
request LED showing status of A/C engagement.
A/C Off for WOT: The scan tool displays the high throttle disable
of the A/C compressor.
A/C Pressure Disable: The scan tool displays the status of the
A/C high side pressure sensor. The scan tool displays Active/Inactive.
A/C Relay Command: The scan tool displays On/Off. The scan tool
displays the control decision for the compressor clutch relay output as determined
by the PCM/ECM.
A/C Relay Circuit History: The scan tool displays the following
message stating the history status of the A/C relay control circuit. The scan tool
displays OK/Open/Short.
A/C Relay Circuit Status: The scan tool displays the following
message stating the present status of the A/C relay control circuit. The scan tool
displays OK/Fault.
A/C Request Signal: The scan tool displays Yes/No. The scan
tool displays Yes when the PCM/ECM receives a message to engage the A/C compressor
clutch. The scan tool displays No when the PCM/ECM receives a message to disengage
the A/C compressor clutch.
A/C Request Switch: The scan tool displays On/Off. The A/C request
switch shows current status of the A/C request switch function on the HVAC control
module.
Ambient Air Temperature Sensor: The scan tool displays -40
to 87.5°C (-40 to 189.5°F). The current value of the ambient air temperature
sensor.
Ambient Light Sensor: The scan tool displays 0-1023 counts
(0-5.00 volts). The voltage applied to the ambient light sensor input
of the BCM.
A/C Switch: The scan tool displays the current status of the
A/C switch engagement at the HVAC control head. The scan tool displays Active/Inactive.
Auto Mode: The scan tool displays the current status of the
A/C auto mode engagement at the HVAC control head. The scan tool displays On/Off.
Battery Voltage Signal: The scan tool displays the level of
battery voltage at the HVAC control module. The scan tool displays 0 - 12 V.
Blower Motor Speed Command: The scan tool displays 0-100%.
The scan tool displays the control decision for the blower motor speed as determined
by the HVAC control module. The scan tool displays 100% when the blower motor is commanded
to maximum speed. The scan tool displays 0% when the blower motor is commanded OFF.
ECT Sensor: The scan tool displays -40 to 215°C (-40
to 419°F) . The voltage applied to the PCM/ECM input from the engine coolant temperature
sensor is converted to a temperature value.
FC Relay 1 Command: The scan tool displays the command status
of the PCM/ECM to relay 1. The scan tool displays On/Off.
FC Relay 2 and 3 Command: The scan tool displays the command
status of the PCM/ECM to relays 2 and 3. The scan tool displays On/Off.
Ignition 1 Signal: The scan tool shows available voltage at
the PCM/ECM. The scan tool displays 0-2 V.
Inside Air Temp. Sensor: The scan tool displays -40 to
185°C (-40 to 365°F). The voltage applied to the HVAC control module
input for the inside air temperature sensor is converted to a temperature value.
Lower Duct Air Temp. Sensor: The scan tool displays 0-255 counts
(0-5.00 volts). The voltage applied to the HVAC control module from the
lower duct air temperature sensor.
Mode Dr. Position: The scan tool displays 0-255 counts
(0-5.00 volts). The voltage applied to the mode door position input of
the HVAC control module.
Mode Dr. Motor Commanded: The scan tool displays 0-255 counts
(0-5.00 volts). The desired position of the mode actuator as determined
by the HVAC control module.
Mode Status: The scan tool displays the HVAC control module
command of Def/Defog/Panel/Bi-level/Floor/Auto mode status.
Outside Air LED: The scan tool displays the command status of
the HVAC control module Outside Air switch LED. The scan tool displays On/Off.
Outside Air Mode Switch: The scan tool displays the command
status of the HVAC control module outside air mode switch. The scan tool displays
On/Off.
Recirculation LED: The scan tool displays the current status
of the recirculation actuator LED. The scan tool displays On/Off.
Recirculation Dr. Motor Command: The scan tool displays 0-255 counts
(0-5.00 volts). The voltage applied to the recirculation door command
input of the HVAC control module.
Recirculation Dr. Position: The scan tool displays 0-255 counts
(0-5.00 volts). The desired position of the recirculation actuator as
determined by the HVAC control module.
Recirculation Switch: The scan tool displays the command status
of the HVAC control module recirculation switch. The scan tool displays Active/Inactive.
Sunload Sensor: The scan tool displays 0-255 counts
(0-5.00 volts). The voltage applied to the sunload input of the HVAC
control module.
Temp Dr. Motor Command: The scan tool displays 0-255 counts
(0-5.00 volts). The voltage applied to the air temperature door command
input of the HVAC control module.
Temp Dr. Motor Position: The scan tool displays 0-255 counts
(0-5.00 volts). The desired position of the air temperature actuator
as determined by the HVAC control module.
Temp Down Switch: The scan tool displays the command status
of the HVAC control module temperature switch. The scan tool displays Active/Inactive.
Temp Up Switch: The scan tool displays the command status of
the HVAC control module temperature switch. The scan tool displays Active/Inactive.
Upper Duct Air Temp. Sensor: The scan tool displays 0-255 counts
(0-5.00 volts). The voltage applied to the HVAC control module from the
upper duct air temperature sensor.