Exhaust Manifold Pipe Replacement LE5
Removal Procedure
Warning: Refer to Exhaust Service Warning in the Preface section.
Warning: Refer to Protective Goggles and Glove Warning in the Preface section.
- Remove the heated oxygen sensor (HO2S). Refer to
Heated Oxygen Sensor Replacement - Sensor 2.
- Remove the exhaust manifold pipe to muffler nuts.
- Remove the exhaust manifold/catalytic converter to exhaust manifold pipe nuts.
- Remove the first muffler hanger insulator.
- Gently pull back and separate the muffler from the exhaust manifold pipe studs.
- Remove the exhaust manifold pipe.
Installation Procedure
- Install the exhaust manifold pipe to the exhaust manifold/catalytic converter.
- Gently pull back and install the exhaust manifold pipe studs to the muffler.
- Install the first muffler hanger insulator.
Caution: Refer to Fastener Caution in the Preface section.
- Install the exhaust manifold/catalytic converter to exhaust manifold pipe nuts and tighten to
30 N·m (20 lb ft).
- Install the exhaust manifold pipe to muffler nuts and tighten to
25 N·m (18 lb ft).
- Install the HO2S. Refer to
Heated Oxygen Sensor Replacement - Sensor 2.