Special Tools
J 39400-A Halogen Leak Detector
Removal Procedure
Note: Refrigerant recovery is not required.
- Remove the refrigerant pressure sensor wire harness connector.
- Remove the refrigerant pressure sensor.
- Remove and discard the O-ring.
Installation Procedure
- Install a new O-ring. Refer to
O-Ring Replacement.
Caution: Refer to Fastener Caution in the Preface section.
- Install the refrigerant pressure sensor and tighten to
5 N·m (44 lb in).
- Install the refrigerant pressure sensor wire harness connector.
- Leak test the fittings using the
J 39400-A .