GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    •  Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptor

DTC P1668: Generator L-Terminal Control Circuit

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Generator L-Terminal Circuit

P1668

P1668

P1668

--

Circuit/System Description

The engine control module (ECM) uses the generator turn ON signal circuit to control the load of the generator on the engine. A high side driver in the ECM applies a voltage to the voltage regulator. This signals the voltage regulator to turn the field circuit ON and OFF. The ECM monitors the state of the generator turn ON signal circuit. The ECM should detect low voltage on generator turn on signal circuit when the ignition is ON and the engine is OFF, or when the charging system malfunctions. With the engine running, the ECM should detect high voltage on the generator turn on signal circuit. The ECM performs tests to determine the status of the generator turn on signal circuit.

Conditions for Running the DTC

The engine is running.

Conditions for Setting the DTC

    • During the Key ON test the ECM detects high voltage on the generator turn on signal circuit for 5 seconds.
    • With the engine running the ECM detects low voltage on the generator turn on signal circuit for 15 seconds.

Action Taken When the DTC Sets

    • The ECM will command the charge indicator to be illuminated on the instrument panel cluster (IPC).
    • The driver information center (DIC) displays the CHECK CHARGE SYSTEM message.
    • The ECM will not illuminate the malfunction indicator lamp (MIL).
    • The ECM will store conditions, which were present when the DTC set as Fail Records data only.

Conditions for Clearing the DTC

The history DTC will clear after 40 consecutive warm-up cycles have occurred without a malfunction.

Reference Information

Schematic Reference

Starting and Charging Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Charging System Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector at the generator.
  2. Ignition ON, test for less than 1 volt between the signal circuit terminal 1 and ground.
  3. If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the ECM.
  4. Engine running, test for greater than 3.5 volts between the signal circuit terminal 1 and ground.
  5. If less than the specified range, test the signal circuit for a short to ground, an open or a high resistance. If the circuit tests normal, replace the ECM.
  6. If all circuit tests normal, test or replace the generator.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Generator Replacement
    •  Control Module References for ECM replacement, setup, and programming