• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The battery energy control module (BECM) monitors the hybrid battery system for an overvoltage condition. A diagnostic is running continuously to verify that the battery pack voltage is not above 52 volts. DTC P1A4E will set if the diagnostic detects that the voltage is above 52 volts.
The ignition is in the RUN position.
Hybrid battery pack voltage greater than 52 volts.
Does not affect hybrid system operation
Hybrid battery pack voltage returns to normal operating range.
Hybrid Energy Storage Schematics
Generator Battery Carrier Description and Operation
Control Module References for scan tool information
J 35616 GM Approved Terminal Test Kit
Warning: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.
Warning: To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect control module. Internal components will still be live, 36V potential, even when the cover has been opened or removed.
Note: In order to avoid damaging BECM X1 and X2 connector terminals, the proper test probes should be used. The proper test probes are as follows:
• | J-35616-65B for female terminals |
• | J-35616-64B for male terminals |
⇒ | If the DTC is history, refer to Testing for Intermittent Conditions and Poor Connections. |
⇒ | If greater than the specified value, replace the battery pack. |
• | X1 terminal 1 to Generator Battery 1-X1 |
• | X1 terminal 11 to Generator Battery 1-X2 |
• | X1 terminal 2 to Generator Battery 2-X2 |
• | X1 terminal 12 to Generator Battery 3-X2 |
⇒ | If not within specified range, replace the voltage sensor harness assembly. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BECM replacement, setup, and programming |