• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The battery energy control module (BECM) monitors the hybrid battery 1 voltage to detect if the minimum voltage is less than the calibration value.
The engine is running.
Minimum module voltage is less than calibration value for 3 seconds.
Minimum module voltage is less than calibration value for 40 ms.
The hybrid system is disabled.
System voltage 11-18 volts.
Generator Battery Carrier Description and Operation
Control Module References for scan tool information