Diagnostic Instructions
DTC Descriptors
DTC P1A0E: Battery Energy Control Module Hybrid Battery Voltage Sensor Circuit Low Voltage
DTC P1A0F: Battery Energy Control Module Hybrid Battery Voltage Sensor Circuit High Voltage
Circuit/System Description
The battery energy control module (BECM) monitors the link voltage using 4 voltage sensors and a internal sensor to detect a low or high voltage condition.
Conditions for Running the DTC
The engine is ON.
Conditions for Setting the DTC
P1A0E
• | The internal voltage sensor is less than 0.5 volts. |
• | The generator battery disconnect control module cover is not installed. |
P1A0F
The internal voltage sensor is greater than 4.5 volts
Action Taken When the DTC Sets
Hybrid system is inactive.
Conditions for Clearing the DTC
Link voltage returns between the calibrated thresholds.
Reference Information
Schematic Reference
Hybrid Energy Storage Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
Generator Battery Carrier Description and Operation
Electrical Information Reference
Scan Tool Reference
Control Module References for scan tool information
Special Tools
J 35616 GM Approved Terminal Test Kit
Circuit/System Testing
Warning: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator
battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts
using a DMM before proceeding.
Warning: To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect control module. Internal components will still be live, 36V potential, even when the
cover has been opened or removed.
Note: In order to avoid damaging BECM X1 and X2 connector terminals, the proper test probes should be used. The proper test probes are as follows:
• | J-35616-65B for female terminals |
• | J-35616-64B for male terminals |
P1A0E
- Remove the generator battery disconnect control module cover. Refer to
Hybrid Battery Service Disconnect/Connect.
- Measure and record the voltage at Main Contactor Relay X2 to ground.
- Depress and hold the service disconnect switch and measure the voltage at Main Contactor Relay X1 to ground. The voltage should read the same as in step 2.
⇒ | If no voltage was measured at Main Contactor Relay X1 with service disconnect switch depressed, replace the BECM. |
- Disconnect connectors X1 and X2 from the BECM.
- Test for less than 6.5 volts between X1 terminal 1 and X2 terminal 1, while depressing the service disconnect switch.
⇒ | If greater than the specified range, replace the BECM. |
- Remove the generator battery cover. Refer to
Generator Battery Temperature Sensor Replacement.
- Measure the resistance between X2 terminal 1 and Main Contactor Relay X1. Should measure between 1.3-1.7 k ohms.
⇒ | If not within specified range, replace the BECM. |
- Measure the resistance between X1 terminal 1 and Generator Battery 1 X1. Should measure between 1.3-1.7 k ohms.
⇒ | If not within specified range, replace the harness assembly. |
P1A0F
- Remove the generator battery disconnect control module cover. Refer to
Hybrid Battery Service Disconnect/Connect.
- Measure and record the voltage at Main Contactor Relay X2 ground. Should read pack voltage.
- Measure the voltage at Main Contactor Relay X1 to ground. Should read no voltage.
⇒ | If greater than the specified range, replace the BECM. |
- Disconnect connectors X1 and X2 from the BECM.
- Remove the generator battery cover. Refer to
Generator Battery Temperature Sensor Replacement.
- Measure the resistance between X2 terminal 1 and Main Contactor Relay X1. Should measure between 1.3-1.7 k ohms.
⇒ | If not within specified range, replace the BECM. |
- Measure the resistance between X1 terminal 1 and Generator Battery 1- X1. Should measure between 1.3-1.7 k ohms.
⇒ | If not within specified range, replace the harness assembly. |
Repair Instructions
Perform the