• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The power inverter module (PIM) temperature 1 sensor is used for overheat protection. The thermistor is located on the control board, near the phase W power MOSFET. The starter/generator control module (SGCM) monitors the inverter temperature sensor to detect the failure of the inverter temperature sensor using rationality of other temperature sensors to determine if it is out of range.
The engine is running.
Inverter temperature sensor is greater than 55°C (131°F) for 2 seconds.
50 percent maximum torque limit
Normal range for 10 seconds
Possible internal failure of temperature sensor
Starter/Generator Description and Operation
Control Module References for scan tool information
Warning: To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect control module. Internal components will still be live, 36V potential, even when the cover has been opened or removed.
⇒ | If the DTC resets, replace the SGCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Generator Control Module Replacement for SGCM replacement, setup, and programming