• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Intake CMP Actuator Solenoid Control | P2088 | P0010 | P2089 | P000A |
Intake CMP Actuator Supply Voltage | -- | P0010 | -- | -- |
Exhaust CMP Actuator Solenoid Control | P2090 | P0013 | P2091 | P000B, P0014 |
Exhaust CMP Actuator Supply Voltage | -- | P0013 | -- | -- |
The camshaft position (CMP) actuator is attached to each camshaft and is hydraulically operated in order to change the angle of the camshaft relative to crankshaft position (CKP). The CMP actuator solenoid is controlled by the control module. The control module sends a pulse width modulated signal to a CMP actuator solenoid. The solenoid controls the amount of engine oil flow to a CMP actuator. The CMP actuator can change the camshaft angle a maximum of 20 degrees. The control module increases the pulse width to accomplish the desired camshaft operation.
• | DTC P0606 is not set. |
• | The ignition is ON. |
• | The ignition voltage is between 10-16 volts. |
The ECM detects an open in the CMP actuator solenoid circuits for greater than 1 second or a cumulative of 5 seconds when the solenoid is commanded OFF.
The ECM detects a short to ground in the CMP actuator solenoid circuits for greater than 1 second or a cumulative of 5 seconds when the solenoid is commanded OFF.
The ECM detects a short to voltage in the CMP actuator solenoid circuits for greater than 1 second or a cumulative of 5 seconds when the solenoid is commanded ON.
DTCs P0010, P0013, P2088, P2089, P2090, P2091 are Type B DTCs.
DTCs P0010, P0013, P2088, P2089, P2090, P2091 are Type B DTCs.
Control Module References for scan tool information
⇒ | If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition circuit fuse is open, test or replace the affected actuator solenoid. |
⇒ | If greater than the specified range, test the control circuit for an open/high resistance. |
⇒ | If not within the specified range, replace the CMP actuator solenoid. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for replacement, setup, and programming |