Special Tools
Removal Procedure
- Open the hood.
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Disconnect the battery.
• | Remove the ground connection from the negative terminal. |
- Remove the engine venting pipe (1).
• | Remove the wiring (2) from the cylinder head cover. |
• | Disconnect the 2 quick-release fittings. |
- Remove the engine management wiring harness.
• | Disconnect the 9 wiring harness plugs. |
- | Valve, intake camshaft adjustment |
• | Remove the 2 wiring harness brackets. |
• | Put the wiring harness to the side. |
- Place a drain pan underneath.
Caution: Refer to Gasoline/Gasoline Vapors Caution in the Preface section.
- Release the fuel pressure via the test connection (1) using
J 34730-1A
/KM-J-34730-91 .
Collect the exiting fuel in a suitable container.
- Remove the fuel return line (1).
• | Remove the quick-release fitting with
J 37088-A
. |
• | Seal the fuel line and the fuel rail with
KM-807
. |
- Remove the fuel rail (2).
Remove the 2 bolts (1).
- Remove the injectors.
• | Remove the 4 retaining clamps (1). |
• | Pull out the 4 injectors. |
Installation Procedure
Important: Inspect the installation position and ensure correct fitting.
- Install the 4 injectors to the fuel rail.
• | Install the 4 new seal rings. |
• | Coat the seal ring with silicone grease (white). |
• | Install the 4 injection valves. |
• | Install the 4 retaining clamps. |
Notice: Refer to Fastener Notice in the Preface section.
- Install the fuel rail.
Tighten
Tighten the 2 bolts to 8 N·m (71 lb in).
- Install the fuel supply line to the fuel rail.
• | Connect the quick release fitting. |
• | Connect into the bracket. |
- Install the engine management wiring harness.
• | Connect the 9 wiring harness plugs. |
- | Intake camshaft actuator |
• | Install the 2 wiring harness brackets. |
- Install the engine vent hose.
• | Connect the 2 quick-release fittings. |
• | Connect the wiring harness to the cylinder head. |
- Connect the battery.
Install the ground connection to the negative terminal.
Tighten
Tighten the ground connection nut to 5 N·m (44 lb in).
- For programming procedures, refer to
Control Module References
.
- Close the hood.