Removal Procedure
- Remove the starter. Refer to
Starter Motor Replacement
.
- Remove the crankshaft position sensor.
• | Disconnect the wiring harness plug (1). |
• | Disconnect the crankshaft position sensor (2) from the bracket. |
Installation Procedure
Notice: Refer to Fastener Notice in the Preface section.
- Install the crankshaft position sensor.
Tighten
Tighten the bolt to 4.5 N·m (40 lb in).
• | Install the wiring harness plug into the bracket. |
• | Install the wiring harness plug. |
- Install the starter. Refer to
Starter Motor Replacement
.