Warning: Refer to Battery Disconnect Warning in the Preface section.
Remove the positive and negative cables.
Remove the bolt.
• | Remove the 2 bolts (1). |
• | Disconnect the wiring harness plug and remove the sensor. |
Caution: Refer to Fastener Caution in the Preface section.
Insert the sensor and connect the wiring harness plug.
Tighten
Tighten the 2 bolts to 6 N·m (53 lb in).
Tighten
Tighten the bolt to 5 N·m (44 lb in).