Removal Procedure
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging.
- Disconnect the compressor hose at the compressor.
- Disconnect the compressor hose (1) from the condenser.
- Disconnect the compressor hose (1) from the evaporator hose.
- Remove the compressor hose assembly.
Installation Procedure
- Replace the seals on the compressor hose at the compressor.
Caution: Refer to Fastener Caution in the Preface section.
- Install the compressor hose to the compressor.
Tighten
Tighten the bolt to 20 N·m (15 lb ft).
- Install a new seal at the compressor hose joint.
- Connect the evaporator hose to the compressor hose.
Tighten
Tighten the bolt to 20 N·m (15 lb ft).
- Install a new seal at the condenser.
- Install the compressor hose (1) to the condenser.
Tighten
Tighten the bolt to 20 N·m (15 lb ft).
- Recharge the refrigerant system. Refer to
Refrigerant Recovery and Recharging.