Removal Procedure


    Object Number: 1936839  Size: LF
  1. Remove the instrument panel (I/P) compartment.
  2. 1.1. Remove the 4 bolts (1).
    1.2. Disconnect the wiring harness plug.
  3. Remove the floor air outlet duct.
  4. Remove the body-bound rivet (2).

Installation Procedure

  1. Install the floor air outlet duct.
  2. Install the body-bound rivet.

    Caution: Refer to Fastener Caution in the Preface section.

  3. Install the I/P compartment.
  4. Install the 4 bolts

    Tighten
    Tighten the 4 bolts to 4 N·m (35 lb in).

  5. Connect the wiring harness plug.