• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Mode Aucuator 8-Volt Reference | 1 | 1 | 1 | -- |
Mode Aucuator Signal | 1 | 1 | 1 | -- |
Mode Aucuator Control A | 1 | 1 | 1 | -- |
Mode Aucuator Control B | 1 | 1 | 1 | -- |
Mode Aucuator Low Reference | -- | 1 | -- | -- |
1. Air Delivery Improper |
The HVAC control module controls the HVAC door actuator to regulate the airflow through the HVAC system. The actuator consists of an electric motor and a potentiometer. The module supplies a low reference and 8-volt reference source voltage to the potentiometer. The HVAC control module monitors the voltage drop across the potentiometer on the door position signal circuit. When the actuator shaft rotates, the voltage on the door position signal circuit changes. The HVAC module controls the direction of the actuator door by changing the polarity of the control circuits.
Inspect the Mode door actuator for the following:
• | A misaligned actuator |
• | Broken or binding linkages or door |
• | An obstruction that prevents the actuator from operating within the full range of motion |
• | Missing seals to the door |
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If less than the specified range, test the 8-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If greater than the specified range, test the 8-volt reference circuit for a short to voltage. If the circuit tests normal, replace the HVAC control module. |
⇒ | If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the HVAC control module. |
⇒ | If less then specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If the test lamp does not illuminate in both directions, test both control circuits for a short to ground or an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.