Warning: Refer to Battery Disconnect Warning in the Preface section.
Note: Only upon replacement of servo motor.
Remove the 2 retainers (1).
3.1. | Remove the 3 bolts (2). |
3.2. | Release and disconnect the wiring harness plug. |
Note: Turn the cam (2). Affix adjuster tool to the adjuster aid (3).
Caution: Refer to Fastener Caution in the Preface section.
Connect the wiring harness plug of defrost actuator.
Tighten
Tighten the 3 bolts to 5 N·m (44 lb in).
Tighten
Tighten the 3 retainers.
Note: Only upon replacement of servo motor.