Warning: Refer to Battery Disconnect Warning in the Preface section.
Note: Only upon replacement of air inlet actuator.
2.1. | Remove the 4 bolts (1). |
2.2. | Disconnect the wiring harness plugs. |
• | Remove the 3 bolts. |
• | Disconnect the wiring harness plug (2). |
• | Release and disconnect the wiring harness plug. |
Caution: Refer to Fastener Caution in the Preface section.
Note: The recirculation actuator can only be fitted in one position and is self-calibrating.
Tighten
Tighten the 3 bolts to 5 N·m (44 lb in).
Tighten
Tighten 4 bolts to 4 N·m (35 lb in).
Note: Only upon replacement of air inlet actuator.