• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Ignition Voltage | C0292 1A | C0292 1A | C0292 1A | C0292 39* |
Low Reference | C0292 1A | C0292 1A | -- | C0292 39* |
CAN Bus High Serial Data | C0292 1A | C0292 1A | C0292 1A | C0292 39* |
CAN Bus Low Serial Data | C0292 1A | C0292 1A | C0292 1A | C0292 39* |
* Internal Sensor Failure |
The electronic brake control module (EBCM) monitors and supplies a 12 volt reference to the yaw sensor with vehicle lateral and longitudinal accelerometer.
Ignition ON.
• | The EBCM detects the sensor voltage is above 18 volts |
• | The EBCM detects the sensor voltage is below 6 volts |
Internal failure of the yaw sensor with vehicle lateral and longitudinal accelerometer.
• | The EBCM disables vehicle stability enhancement system (VSES) and sends a serial data message to the DIC. |
• | The VSES indicator illuminates. |
• | The driver information center (DIC) illuminates the warning indicator/message. |
• | The condition for setting the DTC is no longer present. |
• | The EBCM clears the history DTC when a current DTC is not detected in 100 consecutive drive cycles. |
Antilock Brake System Schematics
Control Module References for scan tool information
Ignition On, verify that DTC C0292 39 is not set.
⇒ | If the DTC is set, replace the yaw sensor with vehicle lateral and longitudinal accelerometer. |
⇒ | If greater than the specified range, test for an open/high resistance in the low reference circuit. If the circuit tests normal, replace the EBCM. |
⇒ | If less than the specified range, test the ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the EBCM. |
⇒ | If greater than the specified range, test the CAN bus low circuit for a short to voltage. |
⇒ | If less than the specified value, test the CAN bus low circuit for a short to ground. |
⇒ | If greater than the specified range, test the CAN bus high circuit for a short to voltage. |
⇒ | If less than the specified value, test the CAN bus high circuit for a short to ground. |
⇒ | If less than the specified value, test the CAN bus circuits for a short to each other. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for EBCM replacement, setup, and programming |