Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Engine Cooling Schematics Connector End View Reference: Cooling System Connector End Views DEFINITION: The engine cooling fan motor runs continuously. | |||
1 | Did you perform the Engine Cooling Diagnostic System Check? | Go to Step 2 | |
2 | Turn ON the ignition, with the engine OFF. Is the engine cooling fan running all the time? | Go to Step 3 | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems |
3 | Remove the cooling fan relay. Did the cooling fan turn OFF? | Go to Step 5 | Go to Step 4 |
4 | Repair the short to B+ in the cooling fan motor supply voltage circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 7 | -- |
5 | Inspect for poor connections at the cooling fan relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 7 | Go to Step 6 |
6 | Replace the cooling fan relay. Did you complete the repair? | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |