Generator Replacement LSJ
Removal Procedure
- Disconnect negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.
- Remove the drive belt. Refer to
Drive Belt Replacement
in Engine Mechanical - 2.0L (LSJ).
- Remove the supercharger. Refer to
Supercharger Replacement
in Engine Mechanical - 2.0L (LSJ).
- Disconnect the generator connectors.
- Remove the generator
bolts.
- Remove the generator from the vehicle.
Installation Procedure
- Position the generator
on the engine.
Notice: Refer to Fastener Notice in the Preface section.
- Install the generator bolts.
Tighten
Tighten the generator bolts to 25 N·m
(18 lb ft).
- Connect the positive battery harness to the generator battery terminal.
Tighten
Tighten the generator terminal nut to 20 N·m
(15 lb ft).
- Connect the generator harness connectors.
- Install the supercharger. Refer to
Supercharger Replacement
in Engine Mechanical - 2.0L (LSJ).
- Install the drive belt. Refer to
Drive Belt Replacement
in Engine Mechanical - 2.0L (LSJ).
- Connect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection
.
Generator Replacement L61
Removal Procedure
- Disconnect negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.
- Remove the drive belt. Refer to
Drive Belt Replacement
in Engine Mechanical - 2.2L (L61).
- Remove the air cleaner outlet resonator. Refer to
Air Cleaner Outlet Resonator Replacement
in Engine Controls - 2.2L
(L61).
- Disconnect the generator connectors.
- Remove the generator bolts.
- Remove the generator from the vehicle.
Installation Procedure
- Position the generator on the engine.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the generator bolts.
Tighten
Tighten the generator bolts to 22 N·m
(16 lb ft).
- Connect the positive battery harness to the generator battery terminal.
Tighten
Tighten the generator terminal nut to 20 N·m
(15 lb ft).
- Connect the generator harness connectors.
- Install the air cleaner outlet resonator. Refer to
Air Cleaner Outlet Resonator Replacement
in Engine Controls - 2.2L
(L61).
- Install the drive belt. Refer to
Drive Belt Replacement
in Engine Mechanical - 2.2L (L61).
- Connect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection
.