Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C Performance Table below? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 150-210 kPa (22-30 psi) | 750-1378 kPa (109-200 psi) | 10°C (50°F) |
19-24°C (66-75°F) | Less than 40% | 150-232 kPa (22-34 psi) | 710-1378 kPa (103-200 psi) | 10°C (50°F) |
Greater than 40% | 159-255 kPa (23-37 psi) | 940-1516 kPa(136-220 psi) | 14°C (57°F) | |
25-29°C (76-85°F) | Less than 35% | 177-255 kPa (26-37 psi) | 1030-1430 kPa (149-208 psi) | 13°C (55°F) |
35-60% | 177-265 kPa (26-38 psi) | 1150-1490 kPa(167-216 psi) | 14°C (57°F) | |
Greater than 60% | 198-285 kPa (29-41 psi) | 1230-1610 kPa(179-234 psi) | 17°C (63°F) | |
30-35°C (86-95°F) | Less than 30% | 198-285 kPa (29-41 psi) | 1270-1660 kPa (184-241 psi) | 16°C (61°F) |
30-50% | 212-298 kPa (31-43 psi) | 1330-1700 kPa(193-247 psi) | 18°C (64°F) | |
Greater than 50% | 212-320 kPa (31-46 psi) | 1378-1760 kPa (200-255 psi) | 21°C (70°F) | |
36-41°C (96-105°F) | Less than 20% | 225-308 kPa (33-45 psi) | 1550-1920 kPa (225-279 psi) | 18°C (64°F) |
20-40% | 232-324 kPa (34-47 psi) | 1570-1920 kPa (228-279 psi) | 21°C (70°F) | |
Greater than 40% | 256-340 kPa (36-49 psi) | 1600-1910 kPa(232-277 psi) | 23°C (73°F) | |
42-46°C (106-115°F) | Less than 20% | 265-333 kPa (38-48 psi) | 1840-2150 kPa (267-312 psi) | 21°C (70°F) |
Greater than 20% | 268-351 kPa (39-51 psi) | 1840-2110 kPa(267-306 psi) | 24°C (75°F) | |
47-49°C (116-120°F) | Below 30% | 298-368 kPa (43-53 psi) | 2070-2340 kPa (300-340 psi) | 26°C (79°F) |
Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C Performance Table below? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 158-234 kPa (23-34 psi) | 468-840 kPa (68-122 psi) | 8°C (45°F) |
19-24°C (66-75°F) | Below 40% | 158-234 kPa (232-34 psi) | 640-1047 kPa (93-152 psi) | 8°C (46°F) |
Above 40% | 172-241 kPa (25-35 psi) | 689-1129 kPa(100-164 psi) | 9°C (48°F) | |
25-29°C (76-85°F) | Below 35% | 172-234 kPa (25-34 psi) | 909-1260 kPa (132-183 psi) | 10°C (50°F) |
35-60% | 179-241 kPa (26-35 psi) | 950-1302 kPa(138-189 psi) | 10°C (50°F) | |
Above 50% | 186-248 kPa (27-36 psi) | 992-1371 kPa(144-199 psi) | 13°C (54°F) | |
30-35°C (86-95°F) | Below 30% | 186-248 kPa (27-36 psi) | 1033-1522 kPa (150-221 psi) | 12°C (52°F) |
30-50% | 192-254 kPa (28-37 psi) | 1171-1570 kPa (170-228 psi) | 13°C (55°F) | |
Above 50% | 199-261 kPa (29-38 psi) | 1219-1660 kPa (177-241 psi) | 14°C (57°F) | |
36-41°C (96-105°F) | Below 20% | 199-261 kPa (29-38 psi) | 1378-1750 kPa (200-254 psi) | 13°C (54°F) |
20-40% | 206-261 kPa (30-38 psi) | 1412-1818 kPa (205-264 psi) | 14°C (61°F) | |
Above 40% | 206-268 kPa (30-39 psi) | 1460-1880 kPa (212-273 psi) | 17°C (73°F) | |
42-46°C (106-115°F) | Below 20% | 213-268 kPa (31-39 psi) | 1639-1977 kPa (238-287 psi) | 14°C (57°F) |
Above 20% | 220-275 kPa (32-40 psi) | 1667-2039 kPa (242-296 psi) | 17°C (61°F) | |
47-49°C (116-120°F) | Below 30% | 234-289 kPa (34-42 psi) | 1901-2232 kPa (276-324 psi) | 17°C (61°F) |