🢒 Air Inlet Valve Actuator Replacement
Removal Procedure
Remove the I/P retainer. Refer to
Instrument Panel Retainer Replacement
in Instrument Panel, Gages, and Console.
Unsnap the recirculation actuator from the HVAC module.
Disconnect the recirculation actuator electrical connector.
Installation Procedure
Connect the recirculation actuator electrical connector.
Align the recirculation actuator with the door shaft and retaining tabs. Snap the actuator into position.
Install the I/P retainer. Refer to
Instrument Panel Retainer Replacement
in Instrument Panel, Gages, and Console.