GM Service Manual Online
For 1990-2009 cars only
Makes
🢒
Saturn
🢒
2007
🢒
ION
🢒
HVAC
🢒
HVAC - Manual
🢒 Air Inlet Valve Actuator Replacement
Removal Procedure
Remove the instrument panel (I/P) retainer. Refer to
Instrument Panel Retainer Replacement
.
Unsnap the recirculation actuator from the HVAC module.
Disconnect the recirculation actuator electrical connector.
Installation Procedure
Connect the recirculation actuator electrical connector.
Align the recirculation actuator with the door shaft and retaining tabs. Snap the actuator into position.
Install the I/P retainer. Refer to
Instrument Panel Retainer Replacement
.